Cooling Water Scale & Corrosion Inhibitor home | solid chemicals | contact
product selector >>
Why use solids?
Our innovative solid chemicals deliver a range of important benefits ... why use solids >>

Improved safety
Improve safety, reduce accidents, coroprate risk and down-time .. improve safety >>

Eco-friendly
Improve your environmental performance ... eco-friendly >>

Cooling Water Scale & Corrosion Inhibitor

Product Name:

SCT6012
Application: Cooling Water Treatment
Brief Description: Scale & Corrosion Inhibitor
Format: Baton (0.36kg) - Solid
Description

SCT6012 is a cooling water treatment scale and corrosion inhibitor developed for “corrosive” water conditions. Based on stabilised phosphate it uses the very latest anti-fouling and corrosion inhibition technologies.

SCT6012 comprises a small solid chemical baton (0.36kg) wrapped in a water soluble bag. It is designed to treat cooling water systems during system start-up, and helps to achieve a suitable inhibitor concentration during this stage.

SCT6012 is also a good “catch up” solution for cooling systems that have lost water or where the inhibitor feed has been absent for some time. It is also good for use in small cooling systems where metering of the inhibitor into the system is not practical.

SCT6012 contains SHMP poly-phos, PBTC phosphonate, DSP, ALCO 540 high performance polymer and triazole. SCT6012 does not contain molybdate or heavy metals such as zinc.

Product Application / Feedrate

At a dosage of 50 ppm in the re-circulating water, this product formulation contains the following:

SHMP poly-phos - 7 ppm
PBTC phosphonate - 4 ppm
DSP - 4 ppm
ALCO 540 (active) - 11 ppm
T-T - 3.5 ppm

This formulation is designed for corrosive water conditions which may or may not be scaling in nature. For more aggressive corrosive conditions, i.e. < 0 LSI, feed rates above 50 ppm may be required.

Recommended Dosage Rates

The initial recommended dosage rate for SCT6012 is 50 ppm in the re-circulating water. However, in practice, rates should be set to suit individual water conditions.

Testing & Control

Phosphonate or polymer test kits suitable for monitoring and controlling the use of SCT6012 are available from SCT. Maintain ortho-PO4 at 8 ppm, and active polymer at 11 ppm.

Feeding

When dosed into a cooling system, operators should attempt to find a high flow area in the sump of the cooling tower or inside an accessible make-up tank. Please note that product dissolution rates will vary depending upon water composition, temperature and flow rate.

Packaging, Storage and Handling

SCT6012 is packaged in cases containing 30 x 0.36kg water-soluble bags, each bag being enclosed in a sealed cardboard tube.

Each case weighs 10.9kg.

For all safety data refer to the latest SCT MSDS.

Store this product in cool, dry area. Correctly stored product will remain effective for between 24 to 36 months.

Additional Information & Technical Support

For additional product information, application advice, pricing or technical support please contact us for further assistance.

 

 


 

 

 

 
 
 
>>
Boilers
 
>>
Cooling
 
>>
Biocides
 
>>
Closed Loops
 
>>
Equipment
 
>>
Test Kits
 

Solid Chemical Technologies
Statham House
Old Trafford
Manchester M32 0FP
United Kingdom

Tel: +44(0) 161 877 2334
Fax: +44(0) 870 135 6389
E: info@solidchemicals.com

 

 

home | solid chemicals | about | faq | partnerships | contact | careers | product selector
boilers | cooling | biocides | closed loops | equipment | test kits | technical support | sales
environmental | media | privacy | site map
 
©2010 Solid Chemicals Limited - all rights reserved