Scale & Corrosion Inhibitor for "Stressed", High Water Hardness

Product Name:

SCT6002
Application: Cooling Water Treatment
Brief Description: Scale & Corrosion Inhibitor for "Stressed" High Water Hardness Conditions
Format: Baton (0.36kg) - Solid
Description

SCT6002 is a multi-functional scale and corrosion inhibitor cooling water treatment product developed for “stressed”, high water hardness conditions. It uses the very latest anti-scaling, anti-fouling and corrosion inhibition technologies. Its scale dispersant and corrosion inhibitors work with conventional chemistry to provide system protection at low product dosage rates.

SCT6002 comprises a small solid chemical baton (0.36kg) wrapped in a water soluble bag. It is designed to treat open cooling tower water systems during system start-up, and helps to achieve a suitable inhibitor concentration during this stage.

SCT6002 is also a good “catch up” solution for cooling systems that have lost water or where the inhibitor feed has been absent for some time. It is also good for use in small cooling systems where metering of the inhibitor into the system is not practical.

SCT6002 contains PBTC phosphonate, HEDP phosphonate, polymaleic acid, Ter-polymer, HPA and triazole.

Product Application / Feedrate

SCT6002 can be used in cooling tower water systems using the following dosage rates. The application rates provided below are based on set water stability indices, however in practice, dosage rates should be set to suit individual water conditions.

Recommended Dosage

Water Quality Range
Dosage*
Test Range
Ryzner Stability Index
Calcium
Alkalinity
Chemical level in recirculating water
Organo-
phosphonate
6.0 – 4.0
200 - 500 ppm
200 – 500 ppm
15 – 25 ppm
3 – 5 ppm
4.0 - 3.0
500 - 800 ppm
500 - 600 ppm
25 –40 ppm
4 – 6 ppm
< 3.0
800+ ppm
600+ ppm
40+ ppm
6 – 8 ppm

* Each baton of SCT6002 yields 25 ppm of product when added to 14.4m3 of system volume/water.

Testing & Control

Organo-phosphonate specific test kits suitable for monitoring and controlling the use of SCT6002 are available from SCT.

Feeding*

When dosed into a cooling system, operators should attempt to find a high flow area in the sump of the cooling tower or inside an accessible make-up tank. Please note that product dissolution rates will vary depending upon water composition, temperature and flow rate.

Packaging, Storage and Handling

SCT6002 is packaged in cases containing 30 x 0.36kg water-soluble bags, each bag being enclosed in a sealed cardboard tube.

Each case weighs 10.9kg.

For all safety data refer to the latest SCT MSDS.

Store this product in cool, dry area. Correctly stored product will remain effective for between 24 to 36 months.

Additional Information & Technical Support

For additional product information, application advice, pricing or technical support please contact us for further assistance.

 

 

 
 
 
>>
Boilers
 
>>
Cooling
 
>>
Biocides
 
>>
Closed Loops
 
>>
Equipment
 
>>
Test Kits
 

Solid Chemical Technologies
Statham House
Old Trafford
Manchester M32 0FP
United Kingdom

Tel: +44(0) 161 877 2334
Fax: +44(0) 870 135 6389
E: info@solidchemicals.com

 

 

home | solid chemicals | about | faq | partnerships | contact | careers | product selector
boilers | cooling | biocides | closed loops | equipment | test kits | technical support | sales
environmental | media | privacy | site map
 
©2010 Solid Chemicals Limited - all rights reserved